KLI

아연 이온화 장치에 의한 물 중 탄산칼슘 스케일 생성 억제 및 제거 효과 측정

Metadata Downloads
Alternative Title
Measurement on the Effect of Inhibiting and Removing Calcium Carbonate Scale in Water by Zinc Ionizing Device
Abstract
Scale inhibition effect of the physical water treatment device that emits zinc cation in water was evaluated. The inhibition effect of scale formation was confirmed by the difference in precipitation amount of calcium carbonate prepared from calcium chloride and sodium carbonate solution with distilled or zinc ionized water. For measuring removal effect of solid calcium carbonate on the filter paper, the ground water passed through the ionizer or not was poured on the filter paper and the differences of weight loss of solid CaCO3 were observed. In the experiments for inhibition, the addition of zinc ion did not appear to change the amount of calcium carbonate precipitate. On the other hand, zinc ion leaving the filter clumped fine calcium carbonate particles to increase turbidity, and it was estimated that scale particles expected to have grown by zinc ions were discharged by water flow. Although the concentration of zinc ions from the ionization device is only tens of ㎍/L, the exposure of zinc ions for a long period of time was expected to slowly release the scale generated on the inside wall of the pipe.
Author(s)
유미선이승혁심학섭양성봉심호
Issued Date
2022
Type
Article
Keyword
Calcium carbonateScale inhibition effectScale removal performanceZinc ionization deviceTap water
DOI
10.26511/JKSET.23.1.9
URI
https://oak.ulsan.ac.kr/handle/2021.oak/13402
Publisher
한국환경기술학회지
Language
한국어
ISSN
1229-8425
Citation Volume
23
Citation Number
1
Citation Start Page
66
Citation End Page
77
Appears in Collections:
Medicine > Nursing
공개 및 라이선스
  • 공개 구분공개
파일 목록
  • 관련 파일이 존재하지 않습니다.

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.