Background and aims: EUS-guided through-the-needle biopsy sampling (EUS-TTNB) using microbiopsy forceps is performed for the accurate diagnosis of pancreatic cystic lesions (PCLs). However, there are no standardized protocols for this procedure, and the amount of data on its efficacy is limited. Here, we evaluated the feasibility, efficacy, and safety of EUS-TTNB in categorizing the types of PCLs and identified the factors associated with diagnostic failure.

Methods: The prospectively collected and maintained EUS-TTNB database at Asan Medical Center was reviewed to identify patients with PCLs who underwent EUS-TTNB between January 2019 and January 2021. The primary outcomes were technical success, diagnostic yield, and adverse events. Factors contributing to diagnostic failure and the discrepancies in the diagnosis made by conventional modalities (ie, EUS morphology, cross-sectional imaging, and cystic fluid analysis) were also evaluated.

Results: Forty-five patients were analyzed. EUS-TTNB was successfully performed in all patients (technical success, 100%). Histologic diagnosis of PCLs was made in 37 patients (diagnostic yield, 82%). When comparing EUS-TTNB with a presumptive diagnosis, EUS-TTNB changed the diagnosis in 10 patients in terms of the categorization of the types of PCLs. The diagnostic yield was significantly higher in those who had 4 or more visible biopsy specimens per session (93%) than in those with fewer than 4 visible biopsy specimens per session (67%; P = .045). During follow-up, 3 patients (7%) experienced adverse events (2 acute pancreatitis, 1 intracystic bleeding), and no life-threatening adverse event occurred.

Conclusions: EUS-TTNB showed high technical feasibility, diagnostic yield, and good safety profile. EUS-TTNB may improve the categorization of the types of PCLs. Studies with standardized procedure protocols are needed to reduce the diagnostic failure for the types of PCLs.
Author(s)
Sung Hyun ChoTae Jun SongDong-Wan SeoDongwook OhDo Hyun ParkSang Soo LeeSung Koo LeeMyung-Hwan Kim
Issued Date
2022
Type
Article
Keyword
Acute diseasesHuman beings
DOI
10.1016/j.gie.2021.09.035
URI
https://oak.ulsan.ac.kr/handle/2021.oak/13599
Publisher
GASTROINTESTINAL ENDOSCOPY
Language
영어
ISSN
0016-5107
Citation Volume
95
Citation Number
2
Citation Start Page
299
Citation End Page
309