Usefulness of Semi-cylindrical Beam Spoiler in Treatment of Early Glottic Cancer Using 6 MV Photon Beam
- Abstract
- Background/aim: To assess the dosimetric influence of a semi-cylindrical beam spoiler (sCBS) for the treatment of early glottic cancer using a 6 MV photon beam.
Patients and methods: The 2D dose distributions were also calculated and measured with and without the sCBS and with a 0.5 cm thick bolus. A retrospective study of 8 patients treated between 2012 and 2018 was performed.
Results: The 2D dose distributions obtained from the treatment planning system (TPS) and film measurements were in good agreement. In the planning study, the V95%, V100%, conformal index (CI), and homogeneity index (HI) of all pPTVs for the sCBS plans were better than those for the open field plans (p<0.01). Especially, sCBS plans had better skin sparing effect than bolus plans (p<0.05).
Conclusion: The sCBS of the 6 MV photon beam could be a useful tool for the treatment of early glottic cancers.
- Author(s)
- Seong Soo Shin; Sohyun Ahn; Seung-Hyup Baek; Jungwon Kwak; Jin Sung Kim; Woo Sang Ahn
- Issued Date
- 2022
- Type
- Article
- Keyword
- 6 MV; Beam spoiler; glottic cancer; photon beam; radiotherapy
- DOI
- 10.21873/invivo.12726
- URI
- https://oak.ulsan.ac.kr/handle/2021.oak/13863
- Publisher
- IN VIVO
- Language
- 영어
- ISSN
- 0258-851X
- Citation Volume
- 36
- Citation Number
- 1
- Citation Start Page
- 465
- Citation End Page
- 472
-