KLI

Fully Automatic Quantitative Measurement of 18F-FDG PET/CT in Thymic Epithelial Tumors Using a Convolutional Neural Network

Metadata Downloads
Abstract
Objectives: The aim of this study was to develop a deep learning (DL)-based segmentation algorithm for automatic measurement of metabolic parameters of 18F-FDG PET/CT in thymic epithelial tumors (TETs), comparable performance to manual volumes of interest.

Patients and methods: A total of 186 consecutive patients with resectable TETs and preoperative 18F-FDG PET/CT were retrospectively enrolled (145 thymomas, 41 thymic carcinomas). A quasi-3D U-net architecture was trained to resemble ground-truth volumes of interest. Segmentation performance was assessed using the Dice similarity coefficient. Agreements between manual and DL-based automated extraction of SUVmax, metabolic tumor volume (MTV), total lesion glycolysis (TLG), and 63 radiomics features were evaluated via concordance correlation coefficients (CCCs) and linear regression slopes. Diagnostic and prognostic values were compared in terms of area under the receiver operating characteristics curve (AUC) for thymic carcinoma and hazards ratios (HRs) for freedom from recurrence.

Results: The mean Dice similarity coefficient was 0.83 ± 0.34. Automatically measured SUVmax (slope, 0.97; CCC, 0.92), MTV (slope, 0.94; CCC, 0.96), and TLG (slope, 0.96; CCC, 0.96) were in good agreement with manual measurements. The mean CCC and slopes were 0.88 ± 0.06 and 0.89 ± 0.05, respectively, for the radiomics parameters. Automatically measured SUVmax, MTV, and TLG showed good diagnostic accuracy for thymic carcinoma (AUCs: SUVmax, 0.95; MTV, 0.85; TLG, 0.87) and significant prognostic value (HRs: SUVmax, 1.31 [95% confidence interval, 1.16-1.48]; MTV, 2.11 [1.09-4.06]; TLG, 1.90 [1.12-3.23]). No significant differences in the AUCs or HRs were found between automatic and manual measurements for any of the metabolic parameters.

Conclusions: Our DL-based model provides comparable segmentation performance and metabolic parameter values to manual measurements in TETs.
Author(s)
Sangwon HanJungsu S OhYong-Il KimSeung Yeon SeoGeun Dong LeeMin-Jae ParkSehoon ChoiHyeong Ryul KimYong-Hee KimDong Kwan KimSeung-Il ParkJin-Sook Ryu
Issued Date
2022
Type
Article
DOI
10.1097/RLU.0000000000004146
URI
https://oak.ulsan.ac.kr/handle/2021.oak/13940
Publisher
CLINICAL NUCLEAR MEDICINE
Language
영어
ISSN
0363-9762
Citation Volume
47
Citation Number
7
Citation Start Page
590
Citation End Page
598
Appears in Collections:
Medicine > Nursing
공개 및 라이선스
  • 공개 구분공개
파일 목록
  • 관련 파일이 존재하지 않습니다.

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.