Background: Despite its proven effectiveness and safety profile, the XEN gel stent (Allergan Inc., CA, USA) for minimally invasive glaucoma surgery (MIGS) has a probability of postoperative complications, including postoperative hypotony, hyphema, stent migration, stent obstruction, bleb fibrosis, and fibrin formation. In particular, the use of adjunctive Mitomycin-C (MMC) might be associated with bleb-related complications, including conjunctival erosion, XEN gel stent exposure, and blebitis. However, there are few studies on XEN gel stent exposure and its management. We describe a case of XEN gel stent exposure with conjunctival erosion 18 months postoperatively, which resolved effectively after combination treatment with a rotational conjunctival flap and amniotic membrane transplantation.
Case presentation: A 74-year-old Korean male patient with diabetes and hypertension underwent uncomplicated ab interno XEN gel stent implantation with a subconjunctival injection of 0.1 cc of 0.02% MMC and presented with low intraocular pressure (IOP) with a well-functioning filtering bleb. Periocular pain and tearing developed 18 months after the initial operation, with mild deterioration of visual acuity to 20/100. Despite conservative medical treatment, the conjunctival erosion was not relieved. Anterior segment optical coherence tomography (AS-OCT) revealed an exposed XEN gel stent with conjunctival erosion. We performed bleb revision surgery using a rotational conjunctival flap and amniotic membrane transplantation. Slit-lamp examination and AS-OCT showed a well-formed moderate bleb without leakage, and IOP continued to be well controlled (14 mm Hg with latanoprost) until six months after bleb revision.
Conclusions: This case report highlights the importance of careful examination, including slit-lamp examination, the Seidel test, and AS-OCT, to identify accurate anatomical positioning and to monitor ocular surface changes after XEN gel stent implantation with MMC or 5-FU. Combination treatment (rotational conjunctival flap and amniotic membrane transplantation) may be relatively safe for persistent XEN gel stent exposure.
Author(s)
Chang Kyu LeeJe Hyun SeoSu-Ho Lim
Issued Date
2022
Type
Article
Keyword
XEN gel stentamniotic membrane transplantationanterior segmentconjunctival erosionrotational conjunctival flap
DOI
10.3390/medicina58111581
URI
https://oak.ulsan.ac.kr/handle/2021.oak/14157
Publisher
Medicina-Lithuania
Language
영어
ISSN
1010-660X
Citation Volume
58
Citation Start Page
1
Citation End Page
8
Appears in Collections:
Medicine > Nursing
공개 및 라이선스
  • 공개 구분공개
파일 목록
  • 관련 파일이 존재하지 않습니다.

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.