Clinical Outcomes of Nanothin Descemet Stripping Automated Endothelial Keratoplasty in Korean Patients: A One-year Follow-up Study
- Abstract
- Purpose: To evaluate the clinical outcomes of nanothin Descemet stripping automated endothelial keratoplasty (DSAEK) in Korean patients with corneal endothelial dysfunction.
Methods: We retrospectively reviewed medical records of the patients who underwent nanothin DSAEK (graft thickness ≤50 μm) due to corneal endothelial dysfunction and followed up more than 1 year. We evaluated best-corrected visual acuity (BCVA), central corneal thickness, and corneal endothelial cell density at preoperative and 1, 3, 6, and 12 months postoperatively.
Results: Sixteen eyes of 16 patients with the mean follow-up period of 13.00 ± 0.96 months were included. The mean graft thickness after deswelling was 45.25 ± 4.59 µm (range, 38.0-50.0 µm). The mean logarithm of the minimum angle of resolution BCVA improved from 1.37 ± 0.53 preoperatively to 0.68 ± 0.46, 0.55 ± 0.35, 0.40 ± 0.25, and 0.39 ± 0.25 at 1, 3, 6, and 12 months postoperatively (p = 0.005, p < 0.001, p < 0.001, and p < 0.001), respectively. The mean central corneal thickness improved from 752.00 ± 129.11 to 555.75 ± 54.66 µm at 12 months postoperatively (p = 0.006). The mean graft endothelial cell density decreased from 2,859.62 ± 228.34 to 1,542.25 ± 627.34 cells/mm2 at 12 months postoperatively (p = 0.012). The postoperative complications included increased intraocular pressure (n = 3, 18.75%) and graft dislocation (n = 1, 6.25%), all of which were successfully managed by anterior chamber paracentesis or rebubbling. No other serious complications were encountered.
Conclusions: Nanothin DSAEK produced significant and stable visual improvements without severe postoperative complications in Korean patients with corneal endothelial dysfunction.
- Author(s)
- Ye Eun Han; Ho Seok Chung; Hun Lee; Jae Yong Kim; Hungwon Tchah
- Issued Date
- 2022
- Type
- Article
- Keyword
- Corneal endothelial dysfunction; Descemet stripping automated endothelial keratoplasty; Nanothin Descemet stripping automated endothelial keratoplasty
- DOI
- 10.3341/kjo.2021.0161
- URI
- https://oak.ulsan.ac.kr/handle/2021.oak/14190
- Publisher
- Korean Journal of Ophthalmology
- Language
- 영어
- ISSN
- 1011-8942
- Citation Volume
- 36
- Citation Number
- 2
- Citation Start Page
- 131
- Citation End Page
- 137
-
Appears in Collections:
- Medicine > Nursing
- 공개 및 라이선스
-
- 파일 목록
-
Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.