KLI

Feasibility of robotic thyroidectomy via hairline incision using da Vinci single port system: Initial experience with 40 consecutive cases

Metadata Downloads
Abstract
Background: This study aimed to introduce our robotic technique, which can minimize dissection extent using the da Vinci SP robotic system via hairline incision.

Methods: Forty patients underwent robotic thyroidectomy using the da Vinci SP robotic system via a hairline incision between February 2020 and April 2021 at Ulsan University Hospital. All procedures were performed successfully by one surgeon using the SP robotic system.

Results: Hemithyroidectomies were performed in 32 patients and total thyroidectomies in eight patients. Central neck dissection was performed in 32 patients. The overall mean operative time was 140.2 ± 50.7 min, and the mean console time was 74.0 ± 42.7 min. All patients were discharged on the second or third day after operation without any complications.

Conclusions: Robotic thyroidectomy using the SP robotic system via hairline incision is technically feasible and safe, with a shorter incision length when compared with that of the Xi system.
Author(s)
Tae-Koon KimMinjung SeoSeol Hoon ParkJin Il KimSoon Joon KimJae Hyun KimYong Han KimMyung Woul Han
Issued Date
2022
Type
Article
Keyword
da Vinci SP robotic systemhairlineretroauricular thyroidectomyrobotic thyroidectomythyroidectomy
DOI
10.1002/hed.27134
URI
https://oak.ulsan.ac.kr/handle/2021.oak/14212
Publisher
HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK
Language
영어
ISSN
1043-3074
Citation Volume
44
Citation Number
10
Citation Start Page
2197
Citation End Page
2205
Appears in Collections:
Medicine > Nursing
공개 및 라이선스
  • 공개 구분공개
파일 목록
  • 관련 파일이 존재하지 않습니다.

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.