KLI

Patient-specific instrumentation improves the reproducibility of preoperative planning for the positioning of baseplate components with reverse total shoulder arthroplasty: a comparative clinical study in 39 patients

Metadata Downloads
Abstract
Background: The application of patient-specific instrumentation (PSI) for reverse total shoulder replacement has been rapidly increasing, which could reduce errors in implant positioning. Although PSI theoretically holds promise, evidence of the accuracy and reliability of PSI in shoulder replacement surgery is limited.

Methods: Thirty-nine shoulders that underwent reverse total shoulder arthroplasty were included in this study and categorized into two groups: the conventional (n = 20) and PSI (n = 19) groups. Screw (length and angle) and baseplate (version, inclination, translation, and rotation) positioning were calculated based on postoperative computed tomography images using a three-dimensional measurement tool. The difference between the values of the preoperative target and postoperative measurement was calculated to evaluate the reproducibility of preoperative planning. Screw involvement in the suprascapular and spinoglenoid notches was assessed. Thus, the correlation between the position of the baseplate and the screws was assessed.

Results: The mean differences between the planned length and angle (anteroposterior and superoinferior angles) and postoperative measurement in the PSI group were significantly smaller than those in the conventional group. Similarly, the mean difference in baseplate rotation between the planned and postoperative measurements in the PSI group was significantly lower than that in the conventional group (4.5° vs 10.6°; P < .001). The spinoglenoid notch was involved in 10 cases in the conventional group and 2 cases in the PSI group, and this difference was significant (P = .014). Overall, the mean difference between the preoperative and postoperative version, inferior inclination, and rotation values for the baseplate position was significantly correlated with the values for screw position (length and angle).

Conclusions: PSI improves the reproducibility of preoperative planning for baseplate and screw positioning and reduces the risk of neurovascular injury in reverse total shoulder arthroplasty.
Author(s)
Jae-Man KwakIn-Ho JeonHyojune KimSeungHyun ChoiHwaYong LeeKyoung Hwan Koh
Issued Date
2022
Type
Article
Keyword
Patient-specific instrumentationbase plate failurebase plate looseningperiscapular nerve injuryreverse total shoulder arthroplastytotal shoulder arthroplasty
DOI
10.1016/j.jse.2021.12.012
URI
https://oak.ulsan.ac.kr/handle/2021.oak/14238
Publisher
JOURNAL OF SHOULDER AND ELBOW SURGERY
Language
영어
ISSN
1058-2746
Citation Volume
31
Citation Number
7
Citation Start Page
1488
Citation End Page
1498
Appears in Collections:
Medicine > Nursing
공개 및 라이선스
  • 공개 구분공개
파일 목록
  • 관련 파일이 존재하지 않습니다.

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.