Percutaneous nephrostomy for nondilated renal collecting system with ultrasound and fluoroscopic guidance: The results of a 10-year experience

Metadata Downloads
Abstract
PURPOSE This study aimed to evaluate the technical success rate, complications, and radiation doses of ultrasound- and fluoroscopy-guided percutaneous nephrostomy (PCN) in patients with a nondi- lated renal collecting system.
METHODS Over a 10-year period, 50 patients were referred for PCN of 60 kidneys with a nondilated renal collecting system. The patients included 22 males and 28 females with a mean age of 63.2 years (range: 35-87 years). The most common reason for PCN in these patients was postoperative ure- teral leaks and/or fistula (21/50 patients). PCN was performed under ultrasound and fluoroscopic guidance. During PCN, intravenous contrast media or diuretics were not used. Technical success rate, complications, procedure time, and radiation exposure of the procedure were retrospec- tively evaluated.

RESULTS Ultrasound- and fluoroscopy-guided PCN for nondilated renal collecting system showed a suc- cess rate of 83.3% (50/60 kidneys) in the initial attempt. Four PCNs were repeated and were suc- cessful after the initial PCN failure. There was 1 major complication of bleeding that required transfusion in 1.9% (1/54) PCNs and there were minor complications of transient gross hematuria through the PCN catheter in 31.5% (17/54) PCNs. Mean duration of the procedure was 15.97 ± 7.81 min and median fluoroscopy time was 4.2 min (range: 1.2-15.3 min). Median dose area product and cumulative dose were 345.37 μGy·m2 (range: 42.57-1659.76 μGy·m2) and 46.9 mGy (range: 7.7-267.8 mGy), respectively.
CONCLUSION Ultrasound- and fluoroscopy-guided PCN for nondilated renal collecting system was feasible with acceptable technical success rate, complication rate, procedure time, and radiation exposure.
Author(s)
Jung Ho WonWoo Jin YangJi Hoon ShinJong Woo KimHee Ho ChuSang Min LeeHo Cheol ChoiSung Eun Park
Issued Date
2022
Type
Article
Keyword
CatheterizationDiureticsFemaleHuman beingsMaleMethodologyMethodsRadiation dosimetry
DOI
10.5152/dir.2022.20728
URI
https://oak.ulsan.ac.kr/handle/2021.oak/14423
Publisher
Diagnostic and Interventional Radiology
Language
영어
ISSN
1305-3825
Citation Volume
28
Citation Number
3
Citation Start Page
244
Citation End Page
248
Appears in Collections:
Medicine > Nursing
공개 및 라이선스
  • 공개 구분공개
파일 목록
  • 관련 파일이 존재하지 않습니다.

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.