Feasibility of lateral mass screw insertion in patients with the risky triad of C1: evaluation of the over-the-arch technique
- Alternative Title
- 10/17 epub
- Abstract
- Objective: The objective of this study was to evaluate the feasibility and complications of the over-the-arch (OTA) technique for screw insertion into the C1 lateral mass in patients in whom conventional techniques (i.e., posterior arch [PA] and inferior lateral mass [ILM]) are not feasible due to 1) PA with a very small height (< 3.5 mm), 2) a caudally tilted PA blocking the inferior part of the C1 lateral mass, or 3) loss of height at the ILM (< 3.5 mm).
Methods: The authors reviewed the medical records of 60 patients who underwent C1 screw fixation with the OTA technique (13 screws) and the PA/ILM technique (107 screws) between 2011 and 2019. Vertebral artery (VA) injuries, screw malposition, and bony union were radiologically assessed. Clinical outcome measures, including Neck Disability Index (NDI), Japanese Orthopaedic Association (JOA) scale score, and occipital neuralgia, were recorded.
Results: Thirteen OTA screws were successfully inserted without any major complications. NDI and JOA scale scores did not show significant differences between the two groups at final follow-up. No VA injuries were recognized during screw insertion. There was no evidence of ischemic damage to the VA or bony erosion in the occiput or atlas. Medial wall violation was observed in 1 screw (7.7%); however, no C0-1, C1-2, or lateral wall violations were observed. No patients developed new-onset neuralgia postoperatively after C1 fixation with the OTA technique.
Conclusions: The OTA technique was safe and useful for C1 screw fixation in patients in whom conventional techniques could not be employed.
- Author(s)
- Hyung Rae Lee; Dong-Ho Lee; Jae Hwan Cho; Eui Seung Hwang; Sang Yun Seok; Sehan Park; Choon Sung Lee
- Issued Date
- 2022
- Type
- Article
- Keyword
- C1 lateral mass screw; atlantoaxial instability; cervical; occipital neuralgia; over-the-arch technique; screw malposition; surgical technique; vertebral artery injury
- DOI
- 10.3171/2021.8.SPINE21695
- URI
- https://oak.ulsan.ac.kr/handle/2021.oak/14655
- Publisher
- JOURNAL OF NEUROSURGERY-SPINE
- Language
- 영어
- ISSN
- 1547-5654
- Citation Volume
- 36
- Citation Number
- 1
- Citation Start Page
- 822
- Citation End Page
- 829
-
Appears in Collections:
- Medicine > Nursing
- 공개 및 라이선스
-
- 파일 목록
-
Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.