A quick Sequential Organ Failure Assessment?negative result at triage is associated with low compliance with sepsis bundles: a retrospective analysis of a multicenter prospective registry
- Abstract
- Objective: We investigated the effects of a quick Sequential Organ Failure Assessment (qSOFA)-negative result (qSOFA score <2 points) at triage on the compliance with sepsis bundles among patients with sepsis who presented to the emergency department (ED).
Methods: Prospective sepsis registry data from 11 urban tertiary hospital EDs between October 2015 and April 2018 were retrospectively reviewed. Patients who met the Third International Consensus Definitions for Sepsis and Septic Shock criteria were included. Primary exposure was defined as a qSOFA score ≥2 points at ED triage. The primary outcome was defined as 3-hour bundle compliance, including lactate measurement, blood culture, broad-spectrum antibiotics administration, and 30 mL/kg crystalloid administration. Multivariate logistic regression analysis to predict 3-hour bundle compliance was performed.
Results: Among the 2,250 patients enrolled in the registry, 2,087 fulfilled the sepsis criteria. Only 31.4% (656/2,087) of the sepsis patients had qSOFA scores ≥2 points at triage. Patients with qSOFA scores <2 points had lower lactate levels, lower SOFA scores, and a lower 28-day mortality rate. Rates of compliance with lactate measurement (adjusted odds ratio [aOR], 0.47; 95% confidence interval [CI], 0.29-0.75), antibiotics administration (aOR, 0.64; 95% CI, 0.52-0.78), and 30 mL/kg crystalloid administration (aOR, 0.62; 95% CI, 0.49-0.77) within 3 hours from triage were significantly lower in patients with qSOFA scores <2 points. However, the rate of compliance with blood culture within 3 hours from triage (aOR, 1.66; 95% CI, 1.33-2.08) was higher in patients with qSOFA scores <2 points.
Conclusion: A qSOFA-negative result at ED triage is associated with low compliance with lactate measurement, broad-spectrum antibiotics administration, and 30 mL/kg crystalloid administration within 3 hours in sepsis patients.
- Author(s)
- Heesu Park; Tae Gun Shin; Won Young Kim; You Hwan Jo; Yoon Jung Hwang; Sung-Hyuk Choi; Tae Ho Lim; Kap Su Han; Jonghwan Shin; Gil Joon Suh; Gu Hyun Kang; Kyung Su Kim
- Issued Date
- 2022
- Type
- Article
- Keyword
- Compliance; Sepsis; Sequential Organ Failure Assessment score
- DOI
- 10.15441/ceem.22.230
- URI
- https://oak.ulsan.ac.kr/handle/2021.oak/15662
- Publisher
- Clinical and Experimental Emergency Medicine
- Language
- 영어
- ISSN
- 2383-4625
- Citation Volume
- 9
- Citation Number
- 2
- Citation Start Page
- 84
- Citation End Page
- 92
-
Appears in Collections:
- Medicine > Nursing
- 공개 및 라이선스
-
- 파일 목록
-
Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.