KLI

The Difference in Tibial Tuberosity to Trochlear Groove Distance Between CT and MRI Arises From the Degree of Knee Flexion During Imaging

Metadata Downloads
Abstract
Background: Tibial tuberosity to trochlear groove distance (TT-TG) has been reported to have different values according to imaging modalities, usually higher in computed tomography (CT) than in magnetic resonance imaging (MRI). This difference is thought to be caused by the degree of knee flexion during imaging, but few studies have aimed to elucidate the cause.

Methods: Five hundred eight patients with knee CT or MRI performed between ages of 6 to 16 years without underlying diseases affecting the musculoskeletal system were included. This study was conducted in 2 statistical ways. (1) Propensity score matching was performed for the imaging modality, and the bony TT-TG was compared between the 2 matched groups. (2) A regression model was fitted with 484 patients with either CT or MRI (a training set), and validation of the fitted model was performed with 24 patients with both CT and MRI simultaneously taken within a week (a test set). The predicted TT-TG values were compared with the measured values.

Results: (1) Eighty-one patients were successfully matched by propensity score (all the standardized mean differences < 0.1) for each modality. In the matched patients, there was no significant difference in TT-TG according to the imaging modality (11.3 ± 3.7 mm for CT, 10.4 ± 3.8 mm for MRI, P = 0.126). (2) For the model fitting, different linear models were fitted before and after 10 degrees of knee flexion angle because there was a sharp change in TT-TG when the knee flexion angle was <10 degrees. The predicted TT-TG values did not significantly differ from the measured values (10.2 ± 4.3 mm vs. 9.0 ± 5.1 mm, P = 0.124).

Conclusions: This study is the first to statistically prove that the difference between TT-TG in MRI and CT originates from the different degrees of knee flexion. In addition, although more studies are needed, authors recommend imaging to be performed with the knee flexed at least 10 degrees for more reliable measurements because TT-TG changes sharply if the knee flexion angle is <10 degrees.
Issued Date
2023
Kunhyung Bae
Amaal Mohammed Aldosari
Michael Seungcheol Kang
Type
Article
DOI
10.1097/BPO.0000000000002481
URI
https://oak.ulsan.ac.kr/handle/2021.oak/16121
Publisher
JOURNAL OF PEDIATRIC ORTHOPAEDICS
Language
한국어
ISSN
0271-6798
Citation Volume
43
Citation Number
9
Citation Start Page
761
Citation End Page
768
Appears in Collections:
Medicine > Nursing
공개 및 라이선스
  • 공개 구분공개
파일 목록
  • 관련 파일이 존재하지 않습니다.

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.