Objectives: To externally validate the performance of a commercial AI software program for interpreting CXRs in a large, consecutive, real-world cohort from primary healthcare centres.

Methods: A total of 3047 CXRs were collected from two primary healthcare centres, characterised by low disease prevalence, between January and December 2018. All CXRs were labelled as normal or abnormal according to CT findings. Four radiology residents read all CXRs twice with and without AI assistance. The performances of the AI and readers with and without AI assistance were measured in terms of area under the receiver operating characteristic curve (AUROC), sensitivity, and specificity.

Results: The prevalence of clinically significant lesions was 2.2% (68 of 3047). The AUROC, sensitivity, and specificity of the AI were 0.648 (95% confidence interval [CI] 0.630-0.665), 35.3% (CI, 24.7-47.8), and 94.2% (CI, 93.3-95.0), respectively. AI detected 12 of 41 pneumonia, 3 of 5 tuberculosis, and 9 of 22 tumours. AI-undetected lesions tended to be smaller than true-positive lesions. The readers' AUROCs ranged from 0.534-0.676 without AI and 0.571-0.688 with AI (all p values < 0.05). For all readers, the mean reading time was 2.96-10.27 s longer with AI assistance (all p values < 0.05).

Conclusions: The performance of commercial AI in these high-volume, low-prevalence settings was poorer than expected, although it modestly boosted the performance of less-experienced readers. The technical prowess of AI demonstrated in experimental settings and approved by regulatory bodies may not directly translate to real-world practice, especially where the demand for AI assistance is highest.
Issued Date
2023
Cherry Kim
Zepa Yang
Seong Ho Park
Sung Ho Hwang
Yu-Whan Oh
Eun-Young Kang
Hwan Seok Yong
Type
Article
Keyword
Artificial intelligenceMulticentre studySoftwareThoracic radiographyValidation study
DOI
10.1007/s00330-022-09315-z
URI
https://oak.ulsan.ac.kr/handle/2021.oak/16557
Publisher
EUROPEAN RADIOLOGY
Language
영어
ISSN
0938-7994
Citation Volume
33
Citation Number
5
Citation Start Page
3501
Citation End Page
3509
Appears in Collections:
Medicine > Nursing
공개 및 라이선스
  • 공개 구분공개
파일 목록
  • 관련 파일이 존재하지 않습니다.

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.