Surgical Navigation System for Pedicle Screw Placement Based on Mixed Reality
- Abstract
- Inaccurate screw insertion has been a major concern in pedicle screw placement in spinal surgery because of the potential for postoperative complications. Efforts to improve screw insertion have led to the development of novel surgical navigation systems. However, current surgical navigation systems have several problems in that the attention of surgeons is frequently interrupted during surgery, and complications occur in their depth perception because of the limitations of 2D monitors. This study proposes a surgical navigation system to address these issues using mixed reality (MR)-based smart glasses. We developed a navigation system that provides 3D visualization of the surgical tool with respect to the patient’s anatomy. It utilizes preoperative surgical planning data to provide visual feedback and guidance. An orthopedic surgeon performed pedicle screw placement with the navigation system in two different environments, using Microsoft HoloLens (HoloLens) and a 2D monitor. The results were evaluated according to procedural time, translational error, angular error, and clinical accuracy. The mean procedural time was 111.3 ± 52.7 s with the HoloLens and 192.1 ± 104.0 s with the 2D monitor. The mean translational error was 2.14 ± 1.13 mm at the entry and 3.14 ± 0.90 mm at the target with HoloLens. With the 2D monitor, the mean translational error was 2.10 ± 0.97 mm and 3.41 ± 2.16 mm at the entry and the target, respectively. The mean angular error was 6.44 ± 1.94 deg with HoloLens and 7.14 ± 4.20 deg with the 2D monitor. All screws were inserted intrapedicularly in both environments. The navigation system enables free visualization, reflects the human eye’s perspective, and retains the advantages of MR-based smart glasses. A navigation system compatible with minimally invasive surgery should be developed in the future.
- Issued Date
- 2023
Seokbin Hwang
Suk-joong Lee
Sungmin Kim
- Type
- Article
- Keyword
- HoloLens; mixed reality; pedicle screw placement; surgical navigation
- DOI
- 10.1007/s12555-023-0083-6
- URI
- https://oak.ulsan.ac.kr/handle/2021.oak/16789
- Publisher
- INTERNATIONAL JOURNAL OF CONTROL AUTOMATION AND SYSTEMS
- Language
- 영어
- ISSN
- 1598-6446
- Citation Volume
- 21
- Citation Number
- 12
- Citation Start Page
- 3983
- Citation End Page
- 3993
-
Appears in Collections:
- Engineering > Medical Engineering
- 공개 및 라이선스
-
- 파일 목록
-
Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.