KLI

Differences in aortic valve area measured on cardiac CT and echocardiography in patients with aortic stenosis

Metadata Downloads
Abstract
Background: A certain proportion of patients with severe aortic stenosis (AS) present with discordant grading between different diagnostic modalities, which raises uncertainty about the true severity of AS. The aim of this study was to compare the aortic valve area (AVA) measured on CT and echocardiography and demonstrate the factors affecting AVA discrepancies.

Methods: Between June 2011 and March 2016, 535 consecutive patients (66.83±8.80 years, 297 men) with AS who underwent pre-operative cardiac CT and echocardiography for aortic valve replacement were retrospectively included. AVA was obtained by AVA on echocardiography (AVAecho) and CT (AVACT) using a measurement of the left ventricular outflow tract on each modality and correlations between those measures were evaluated. Logistic regression analysis was performed to identify factors affecting the discordance for grading severe AS.

Results: The AVACT and AVAecho showed a high correlation (r: 0.79, P <0.001) but AVACT was larger than the AVAecho (difference 0.26 cm2, P <0.001). By using the cut-off values of AVACT (<1.2 cm2) and AVAecho (<1.0 cm2) for diagnosing severe AS, the BSA (odds ratio [OR]: 68.03, 95% confidence interval [CI]: 5.45-849.99; P = 0.001), AVAecho (OR: 1.19, 95%CI: 1.14-1.24; P <0.001), tricuspid valve morphology (OR: 2.83, 95%CI: 1.23-6.50; P = 0.01), and normalized annulus area (OR: 1.02; 95%CI:1.02-1.03; P <0.001) were significant factors associated with the discordance between the AVAecho and AVACT.

Conclusion: Patients with larger BSA, AVAecho, and annulus, and tricuspid valve morphology were associated with the AVA discordance between the echocardiography and CT. Complementary use of CT with echocardiography for grading severe AS could be helpful in such conditions.
Issued Date
2023
Jooae Choe
Hyun Jung Koo
Se Jin Choi
Seung-Ah Lee
Dae-Hee Kim
Jong-Min Song
Duk-Hyun Kang
Jae-Kwan Song
Joon-Won Kang
Dong Hyun Yang
Type
Article
Keyword
Medicine and health sciencesDiagnostic medicineDiagnostic radiologyUltrasound imagingEchocardiographyResearch and analysis methodsImaging techniquesRadiology and imagingNeuroimagingComputed axial tomographyBiology and life sciencesNeuroscienceTomographyAnatomyCardiovascular anatomyHeartAortic valveSurgical and invasive medical proceduresClinical medicineSigns and symptomsStenosisCardiovascular proceduresCoronary artery bypass graftingBlood vesselsAortaMathematical and statistical techniquesStatistical methodsRegression analysisPhysical sciencesMathematicsStatistics
DOI
10.1371/journal.pone.0280530
URI
https://oak.ulsan.ac.kr/handle/2021.oak/17596
Publisher
PLOS ONE
Language
영어
ISSN
1932-6203
Citation Volume
18
Citation Number
1
Citation Start Page
1
Citation End Page
14
Appears in Collections:
Medicine > Nursing
공개 및 라이선스
  • 공개 구분공개
파일 목록
  • 관련 파일이 존재하지 않습니다.

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.