Diagnosis of parathyroid incidentaloma detected on thyroid ultrasonography: the role of fine-needle aspiration cytology and washout parathyroid hormone measurements
- Abstract
- Purpose
The aim of this study was to assess the diagnostic role of fine-needle aspiration cytology (FNAC) and analyze factors associated with false-negative FNAC results in patients with parathyroid incidentaloma who were referred for ultrasonography (US)-guided fine-needle aspiration (FNA) of thyroid nodules.
Methods
In this study, 121 patients with suspected parathyroid lesions were enrolled. The patients underwent US-guided FNAC with measurements of washout parathyroid hormone (PTH) between January 2015 and May 2020. The diagnostic performance of FNAC for the diagnosis of parathyroid lesions was assessed using surgical results and elevated washout PTH as a reference standard. The clinical and radiologic features associated with false-negative results on FNAC for the diagnosis of parathyroid lesions were evaluated.
Results
Among the 121 nodules assessed, 38 were parathyroid lesions (31.4%), and 83 were non-parathyroid lesions (68.6%). The diagnostic performance of FNAC for parathyroid incidentaloma showed a sensitivity of 31.6% (12/38), specificity of 100% (83/83), positive predictive values of 100% (12/12), negative predictive values of 76.1% (83/109), and accuracy of 78.5% (95/121). The FNAC results of non-parathyroid lesions included thyroid nodules, lymph nodes, neurogenic tumors, and fat tissue. True-positive results on FNAC were significantly associated with performing FNA twice (58.3% vs. 23.1%, P=0.043).
Conclusion
Considering the low sensitivity of FNAC, measuring washout PTH in addition to FNAC may help accurately diagnose parathyroid incidentaloma on thyroid US. Further, the falsenegative rate for FNAC can be reduced by obtaining two or more FNA samples.
- Author(s)
- Boeun Lee; Sae Rom Chung; Young Jun Choi; Tae-Yon Sung; Dong Eun Song; Tae Yong Kim; Jeong Hyun Lee; Jung Hwan Baek
- Issued Date
- 2023
- Type
- Article
- Keyword
- Parathyroid incidentaloma; Neck ultrasonography; Fine-needle aspiration cytology; Parathyroid hormone
- DOI
- 10.14366/usg.22105
- URI
- https://oak.ulsan.ac.kr/handle/2021.oak/17726
- Publisher
- ULTRASONOGRAPHY
- Language
- 영어
- ISSN
- 2288-5919
- Citation Volume
- 42
- Citation Number
- 1
- Citation Start Page
- 129
- Citation End Page
- 135
-
Appears in Collections:
- Medicine > Nursing
- 공개 및 라이선스
-
- 파일 목록
-
Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.