Abstract
Abstract

Factors affecting alarm management activities
for medical devices among intensive care unit nurses

Lee, Je Kyung
Department of Nursing
The Graduate School, University of Ulsan
Supervised by Prof. Jang, Aelee


This study aimed to investigate the perception of medical device alarms, alarm fatigue, patient safety culture, and alarm management activities among intensive care unit (ICU) nurses, and to identify factors affecting alarm management activities for medical devices. The data collection period was from February 2, 2021 to February 28, 2021. The participants in this study were 156 ICU nurses at two tertiary general hospitals located in B Metropolitan City, and one tertiary general hospital and one general hospital located in U City, South Korea, who understood the purpose of the study and agreed to participate in this study. This study was conducted after receiving approval from the Institutional Review Committee (IRB) at U University. This study used a structured questionnaire that consists of a total of 118 items, including 10 items regarding general characteristics, items regarding alarm-related characteristics, 18 items regarding perception of alarms, nine items regarding the importance of alarm-related issues, eight items regarding alarm fatigue, 44 items regarding patient safety culture, and 22 items regarding alarm management activities. The collected data were analyzed with a t-test, ANOVA, Scheffé test, Pearson's correlation coefficient, and multiple regression analysis using the SPSS 25.0 program.

The results of this study are as follows:

1. By gender,10.3% were men and 89.7% were women. The average age was 28.89±5.90 years old, with 69.2% in their 20s, 24.4% in their 30s, and 6.4% in their 40s. In terms of marital status, 27.6% were married, and 72.4% were unmarried. In terms of education level, 78.8% had an associate's degree, 16.7% had a bachelor's degree, and 4.5% had a master's degree or higher. In terms of hospital size, 64.1% were tertiary hospital nurses, and 35.9% were general hospital nurses. In terms of working department, 48.1% were nurses working in internal medicine ICU, 34.0% in surgical ICU, and 17.9% in cardiovascular ICU. The average clinical career length was 5.83±6.25 years, with 39.7% having a clinical career length of < 3 years, 22.4% having a clinical career length of 3 to 5 years, 21.8% having a clinical career length of 5 to 10 years, and 16% having a clinical career length of ≥ 10 years. The average number of patients one nurse was in charge of was 2.85±0.64. In terms of shift patterns, 96.8% were three-shift workers, and 3.2% were two-shift workers. The average level of physical fatigue in the past one week was 7.41±1.43 out of a total of 10 points.

2. With regard to the alarm-related characteristics of the participants, the medical devices that emit alarms included ventilators (98.1%), infusion pumps (96.8%), physiological monitors (93.6%), continuous renal replacement therapy equipment (80.1%), and the hemodialyzer (66.7%). With regard to alarm management, 92.3% reported that when a medical device sounded an alarm, the causes of the alarm were solved. The medical device with the highest alarm fatigue was physiological monitors (48.8%), followed by ventilators (24.4%), continuous renal replacement therapy equipment (18.6%), and infusion pumps (5.1%). In the recent two years, 80.1% received education on how to use medical devices, and 64.7% received education on medical device alarm management. As for the education methods on how to use medical devices, 76.8% were given a brief explanation in the ICU while on duty, and the medical devices in which they were educated included ventilators (83.2%), fluid infusion pumps (62.4%), continuous renal replacement therapy equipment (61.6%), and physiological monitors (52.8%). As for the education method on alarm management, 70.3% of the participants were briefed in the ICU while on duty, and the medical devices in which they were educated included ventilators (79.2%), infusion pumps (68.3%), continuous renal replacement therapy (61.4%), and physiological monitors (55.4%). In addition, 37.8% experienced medical device alarm-related patient safety accidents, of whom 10.9% had direct experiences and 26.9% had indirect experiences. Among those who had experienced such accidents, 67.8% received feedback such as recommended education on medical device alarms or guideline changes. The mean score for the need for alarm-related regular education was 4.05±0.76 out of 5 points.

3. The mean score for the perception of medical device alarms among the participants was 3.48±0.30 out of 5 points. Among alarm-related issues, the perceived most important issue was that “Frequent false alarms, which lead to reduced attention or response to alarms when they occur.” The score for alarm fatigue among the participants was 3.58±0.50 out of 5 points. The score for patient safety culture was 3.39±0.23 out of 5 points. The score for alarm management activities among the participants was 2.66±0.37 out of 4 points.

4. There was a statistically significant difference in perception of alarms according to education level (F=3.897, p=.022) among the participants’ general characteristics and alarm-related characteristics.

5. There was a statistically significant difference in alarm fatigue according to the presence or absence of experiencing patient safety accidents (F=3.730, p=.026).

6. There was a statistically significant difference in patient safety culture according to the presence or absence of receiving education on how to use medical device (t=3.492, p=.001) and the presence or absence of receiving education on medical device alarm management (t=3.148, p=.002).

7. There was a statistically significant difference in alarm management activities according to hospital size (t=-3.482, p=.001), the presence or absence of receiving education on how to use medical devices (t=3.295, p=.001), and the presence or absence of receiving education on medical device alarm management (t=3.788, p=<.001).

8. The alarm management activities were negatively correlated with the average number of
patients in charge of nurses (r=-.283, p=<.001), alarm fatigue (r=-.173, p=.031), and the perceived third-most important alarm-related issue that “Over-reliance on alarms to call attention to patient problems.” (r=-.283, p=.048). Patient safety culture (r=.251, p=.002) was positively correlated with the perceived ninth-most important alarm-related issue that “Difficulty in hearing alarms when they occur.” (r=.224, p=.005).

9. To identify the factors affecting alarm management activities among the participants, a
hierarchical multiple regression analysis was performed by inputting the participants’ alarm-related characteristic variables in the first stage, alarm perception and alarm fatigue variables in the second stage, and patient safety culture variables in the third stage. The most significant explanatory variable was the perceived important alarm-related issue “Difficulty in hearing alarms when they occur.” (β=-.254, p=.001), followed by patient safety culture (β=.174, p=.025), and hospital size (β=.226, p=.028). The explanatory power of these variables for alarm management activities was 23.0% (F=6.773, p<.001, adj.R2=.230).

In conclusion, this study determined the levels of perception of medical device alarms, alarm fatigue, patient safety culture, and alarm management activities among ICU nurses, and found that the factors affecting alarm management activities included a perceived important alarm-related issue that “Difficulty in hearing alarms when they occur.”, patient safety culture, and hospital size. In addition, the results of this study can be used as basic data for the development of intervention strategies and education to reduce alarm fatigue among ICU nurses and promote their alarm management activities.| 국문 초록


집중치료실 간호사의 의료장비 알람관리 활동에
영향을 미치는 요인

본 연구는 집중치료실 간호사를 대상으로 의료장비에 대한 알람인식, 알람피로, 환자안전문화, 알람관리 활동의 정도를 확인하고 알람관리 활동의 영향요인을 파악하였다. 자료수집 기간은 2021년 2월 2일부터 2월 28일까지였으며, 연구 대상은 B광역시 소재 2개 상급종합병원, U시 소재 1개 상급종합병원과 1개 종합병원에서 연구의 목적을 이해하고 연구 참여에 동의한 집중치료실 간호사 156명으로 U대학교 생명윤리위원회의 승인 후 진행되었다. 연구도구는 구조화된 설문지로 일반적 특성 10문항, 알람 관련 특성 7문항, 알람인식 18문항, 알람 관련 문제 중요도 순위 9문항, 알람피로 8문항, 환자안전문화 44문항, 알람관리 활동 22문항이며 총 118문항으로 구성되어 있다. 수집된 자료는 SPSS 25.0 프로그램을 이용하여 분석하였고, 연구목적에 따라 t-test와 ANOVA, Scheffé test, Pearson’s correlation coefficient, Multiple regression analysis을 사용하였다.

본 연구의 결과는 다음과 같다.

1. 대상자의 일반적 특성 중 성별은 남자가 10.3%, 여자가 89.7%였으며, 평균연령은 28.89±5.90세로 20대가 69.2%, 30대가 24.4%, 40대가 6.4%였다. 결혼상태는 기혼이 27.6%, 미혼이 72.4%였다. 학력은 학사가 78.8%, 전문학사가 16.7%, 석사이상은 4.5%였고, 병원규모에 따른 상급종합병원 간호사는 64.1%, 종합병원 간호사는 35.9%였다. 근무부서는 내과계 집중치료실이 48.1%, 외과계 집중치료실이 34.0%, 심혈관계 집중치료실이 17.9%였다. 총 임상경력은 평균 5.83±6.25년으로 3년 미만이 39.7%, 3년에서 5년 미만이 22.4%, 5년에서 10년 미만이 21.8%, 10년 이상이 16%였다. 집중치료실 근무경력은 평균 4.54±4.66년으로 3년 미만이 47.4%, 3년에서 5년 미만이 21.2%, 5년에서 10년 미만이 21.2%, 10년 이상이 10.3%였다. 간호사 한명이 평균적으로 담당하는 환자의 수는 평균 2.85±0.64명이었으며, 근무형태는 3교대가 96.8%, 2교대는 3.2%였다. 최근 1주일 내 신체적으로 느끼는 피로의 정도는 총 10점 만점에 평균 7.41±1.43점이었다.

2. 대상자의 알람 관련 특성 중 알람을 유발하는 의료장비는 인공호흡기가 98.1%, 수액주입펌프 96.8%, 생리학적 모니터 93.6%, 지속적 신대체 요법 장비 80.1%, 혈액투석기 66.7%였다. 의료장비 알람유발 시 관리방법으로 알람의 원인을 해결한다는 응답이 92.3%였고, 알람피로도가 가장 높은 의료장비로는 생리학적 모니터가 48.8%, 인공호흡기가 24.4%, 지속적 신대체 요법 장비가 18.6%, 수액주입펌프는 5.1%였다. 최근 2년 이내 의료장비 사용방법에 대한 교육은 80.1%가 받았고, 최근 2년 이내 의료장비 알람관리 방법에 대한 교육은 64.7%가 받았다. 의료장비 사용방법에 대한 교육방법은 근무 중 짧은 집중치료실 내 설명이 76.8%였고, 교육받은 의료장비는 인공호흡기 83.2%, 수액주입펌프 62.4%, 지속적 신대체 요법 장비 61.6%, 생리학적 모니터 52.8%였다. 알람관리 방법에 대한 교육방법 역시 근무 중 짧은 집중치료실 내 설명이 70.3%였고, 교육받은 의료장비는 인공호흡기 79.2%, 수액주입펌프 68.3%, 지속적 신대체 요법 장비 61.4%, 생리학적 모니터 55.4%였다. 의료장비 알람 관련 환자안전사고는 37.8%가 경험했으며 그 중 직접 경험은 10.9%, 간접 경험은 26.9%였다. 경험자 중 67.8%는 의료장비 알람과 관련된 개선교육이나 지침변경 등의 피드백을 받았다. 알람과 관련하여 정기적인 교육의 필요성은 총 5점 만점에 평균 4.05±0.76점이었다.

3. 대상자의 알람인식은 총 5점 만점에 평균 3.48±0.30이었다. 알람과 관련된 문제 중 중요하다고 인식하는 1위는 ‘자주 발생하는 위양성 알람으로 인해 알람에 대한 경각심과 대처가 감소한다.’였다. 대상자의 알람피로는 총 5점 만점에 3.58±0.50이었고, 환자안전문화는 총 5점 만점에 3.39±0.23점이었다. 대상자의 알람관리 활동의 정도는 총 4점 만점에 2.66±0.37점이었다.

4. 대상자의 일반적 특성 및 알람 관련 특성에 따른 알람인식은 교육정도(F=3.897, p=.022)에서 통계적으로 유의한 차이가 있었다.

5. 대상자의 일반적 특성 및 알람 관련 특성에 따른 알람피로는 환자안전사고 경험여부(F=3.730, p=.026)와 통계적으로 유의한 차이가 있었다.

6. 대상자의 일반적 특성 및 알람 관련 특성에 따른 환자안전문화는 의료장비 사용방법 교육 유무(t=3.492, p=.001), 의료장비 알람관리 방법 교육 유무(t=3.148, p=.002)에서 통계적으로 유의한 차이가 있었다.

7. 대상자의 일반적 특성 및 알람 관련 특성에 따른 알람관리 활동은 병원규모(t=-3.482, p=.001), 의료장비 사용방법 교육 유무(t=3.295, p=.001), 의료장비 알람관리 방법 교육 유무(t=3.788, p=<.001)에서 통계적으로 유의한 차이가 있었다.

8. 알람관리 활동은 간호사의 평균 담당 환자 수(r=-.283, p=<.001)와 알람피로(r=-.173, p=.031), 알람 관련 문제 중요도 3위인 ‘환자상태 변화를 감지하기 위해 알람에 과도하게 의존한다.’(r=-.283, p=.048)는 음의 상관관계가 있었고, 환자안전문화((r=.251, p=.002)와 알람 관련 문제 중요도 9위인 ‘알람 소리가 잘 안 들린다.’(r=.224, p=.005)는 양의 상관관계가 있었다.



9. 대상자의 알람관리 활동에 미치는 영향요인을 확인하기 위해 첫 번째 단계에는 대상자의 알람 관련 특성 변수를, 두 번째 단계에는 알림인식과 알람피로를, 세 번째 단계에는 환자안전문화를 입력하여 위계적 다중회귀분석 방법으로 분석하였다. 개별 변수로는 알람 관련 문제 중요도 중 ‘알람소리가 잘 안 들린다.’(β=-.254, p=.001), 환자안전문화(β=.174, p=.025), 병원규모(β=.226, p=.028)의 순서로 유의한 설명변수였으며, 이 변수의 알람관리 활동에 대한 설명력은 23.0%였다(F=6.773, p<.001, adj.R2=.230).

결론적으로 본 연구는 집중지료실 간호사의 의료장비에 대한 알람인식, 알람피로, 환자안전문화, 알람관리 활동의 정도를 확인하고, 알람 관련 문제 중요도 중 ‘알람소리가 잘 안 들린다.’, 환자안전문화, 병원규모가 알람관리 활동에 영향을 미치는 요인임을 확인하였다. 또한 본 연구의 결과는 집중치료실 간호사의 알람피로를 줄이고 알람관리 활동 증진을 위한 중재 전략과 교육개발을 위한 기초 자료로 활용할 수 있을 것이다.
Author(s)
이제경
Issued Date
2021
Awarded Date
2021-08
Type
Dissertation
Keyword
의료장비 알람''알람피로''알람관리''환자안전''집중치료실 간호사'
URI
https://oak.ulsan.ac.kr/handle/2021.oak/5637
http://ulsan.dcollection.net/common/orgView/200000507982
Alternative Author(s)
Lee Je Kyung
Affiliation
울산대학교
Department
일반대학원 간호학과
Advisor
장애리
Degree
Master
Publisher
울산대학교 일반대학원 간호학과
Language
kor
Appears in Collections:
Nursing > 1. Theses(Master)
공개 및 라이선스
  • 공개 구분공개
파일 목록

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.