The mechanical characteristics and performance evaluation of a newly developed silicone airway stent (GINA stent)
- Abstract
- Central airway obstruction (CAO) can be attributed to several benign or malignant conditions. Although surgery is the preferred therapeutic option for the management of CAO, bronchoscopic treatment can be performed in scenarios where the surgical procedure is not possible. Recent years have witnessed several improvements in the field of bronchoscopic treatment, especially with regard to airway stents. Current research involves new attempts to overcome the existing shortcomings pertaining to the stents (migration, mucostasis, and granulation tissue formation). The authors have recently developed a new silicone airway stent (GINA stent) with an anti-migration design, dynamic structure that enables the reduction of stent cross-sectional area, and radio-opacity. The present study aimed to evaluate the mechanical characteristics and performance of the novel GINA stent using a porcine tracheal stenosis model. In the current study, all the tests involved the comparison of the GINA stent [outer diameter (OD, mm): 14; length (L, mm): 55] with the Dumon stent (OD: 14; L: 50). The mechanical tests were performed using a digital force gauge, in order to determine the anti-migration force, expansion force, and flexibility. The present study evaluated the short-term (3 weeks) performance of the two stents after implantation [GINA (n=4) vs. Dumon (n=3)] in the porcine tracheal stenosis model. The results pertaining to the comparison of the mechanical properties of the GINA and Dumon stents are stated as follows: anti-migration force (18.4 vs. 12.8 N, P=0.008); expansion force (11.9 vs. 14.5 N, P=0.008); and flexibility (3.1 vs. 4.5 N, P=0.008). The results pertaining to the comparison of the short-term performance of the GINA and Dumon stents are stated as follows: mucus retention (0/4 vs. 0/3); granulation tissue formation (0/4 vs. 0/3); and migration (1/4 vs. 2/3). The GINA stent displayed better mechanical properties and comparable short-term performance, compared to the Dumon stent.
- Author(s)
- 정화식; 채강희; 김진형; 박취용; 임소연; 박순은; 김호창; 이영재; 강성권; 김돈한; 이용직; 이태훈
- Issued Date
- 2021
- Type
- Article
- Keyword
- Airway silicone stent; Tracheal stenosis; Porcine model
- DOI
- 10.1038/s41598-021-87142-w
- URI
- https://oak.ulsan.ac.kr/handle/2021.oak/7029
https://ulsan-primo.hosted.exlibrisgroup.com/primo-explore/fulldisplay?docid=TN_cdi_doaj_primary_oai_doaj_org_article_dbfaa77322fb45b69e07ec308940838a&context=PC&vid=ULSAN&lang=ko_KR&search_scope=default_scope&adaptor=primo_central_multiple_fe&tab=default_tab&query=any,contains,The%20mechanical%20characteristics%20and%20performance%20evaluation%20of%20a%20newly%20developed%20silicone%20airway%20stent%20(GINA%20stent)&offset=0&pcAvailability=true
- Publisher
- SCIENTIFIC REPORTS
- Location
- 영국
- Language
- 영어
- ISSN
- 2045-2322
- Citation Volume
- 11
- Citation Number
- 1
- Citation Start Page
- 0
- Citation End Page
- 0
-
Appears in Collections:
- Medicine > Medicine
- 공개 및 라이선스
-
- 파일 목록
-
Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.