Abstract
To apply a new airway treatment to humans, preclinical studies in an appropriate animal model is needed. Canine, porcine and leporine tracheas have been employed as animal airway stenosis models using various methods such as chemical caustic agents, laser, and electrocautery. However, existing models take a long time to develop (3-8 weeks) and the mechanism of stenosis is different from that in humans. The aim of the present study was to establish a new and fast tracheal stenosis model in pigs using a combination of cuff overpressure intubation (COI) and electrocautery. Fourteen pigs were divided into three groups: tracheal cautery (TC) group (n=3), COI group (n=3), and COI-TC combination group (n=8). Cuff overpressure (200/400/500 mmHg) was applied using a 9-mm endotracheal tube. Tracheal cautery (40/60 watts) was performed using a rigid bronchoscopic electrocoagulator. After intervention, the pigs were observed for 3 weeks and bronchoscopy was performed every 7 days. When the cross-sectional area decreased by > 50%, it was confirmed that tracheal stenosis was established. The time for tracheal stenosis was 14 days in the TC group and 7 days in the COI-TC combination group. In the COI group, no stenosis occurred. In the COI-TC group, electrocautery (40 watts) immediately after intubation for >1 h with a cuff pressure of 200 mmHg or more resulted in sufficient tracheal stenosis within 7 days. Moreover, the degree of tracheal stenosis increased in proportion to the cuff pressure and tracheal intubation time. The combined use of cuff overpressure and electrocautery helped to establish tracheal stenosis in pigs rapidly.
Author(s)
김진형안종준제갈양진배수현박순은정문식박주익차희정이용직이태훈
Issued Date
2021
Type
Article
Keyword
pig tracheal stenosis modelcuff overpressureelectrocautery
DOI
10.1007/s11596-021-2351-0
URI
https://oak.ulsan.ac.kr/handle/2021.oak/7030
https://ulsan-primo.hosted.exlibrisgroup.com/primo-explore/fulldisplay?docid=TN_cdi_proquest_miscellaneous_2515683027&context=PC&vid=ULSAN&lang=ko_KR&search_scope=default_scope&adaptor=primo_central_multiple_fe&tab=default_tab&query=any,contains,Rapid%20Establishment%20of%20Tracheal%20Stenosis%20in%20Pigs%20Using%20Endotracheal%20Tube%20Cuff%20Overpressure%20and%20Electrocautery&offset=0&pcAvailability=true
Publisher
CURRENT MEDICAL SCIENCE
Location
미국
Language
영어
ISSN
2096-5230
Citation Volume
41
Citation Number
2
Citation Start Page
329
Citation End Page
335
Appears in Collections:
Medicine > Medicine
공개 및 라이선스
  • 공개 구분공개
파일 목록
  • 관련 파일이 존재하지 않습니다.

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.