KLI

A modified method of measuring plasma volume with indocyanine green: reducing the frequency of blood sampling while maintaining accuracy

Metadata Downloads
Abstract
Among various methods for measuring the plasma volume (PV), the indocyanine green (ICG) dilution technique is a relatively
less invasive method. However, the ICG method is rather cumbersome because 10 blood samples need to be obtained
within a short time after ICG administration. Thus, reducing the frequency of blood sampling while maintaining the accuracy
would facilitate plasma volume measurement in clinical situations. We here developed a modified method to measure
plasma volume using 2260 ICG plasma concentration data from 115 surgical patients. The mean relative error (MRE) and
the percentage of cases with relative error (RE) greater than 5% in total (PRE) were used to quantify the difference between
plasma volumes obtained by the original and modified methods. RE was determined as follows. RE(%) = (PV obtained by
original method (PVoriginal)?PV obtained by modified method (PVmodified))/PVoriginal × 100. PVmodified was assumed to be
equal to PVoriginal when the RE was < 5%. When the number of samples selected for the plasma volume estimation was 4 or
less, the PRE was mostly 10% or more. Five out of the 10 blood samples (order: 1st, 2nd, 3rd, 9th, and 10th) showed similar
accuracies with the plasma volume obtained by the original method (original: 2.72 ± 0.64 l, modified: 2.72 ± 0.65 l). This
modified method may be able to aptly replace the original method and lead to a wider clinical application of the ICG dilution
technique. Further validation is needed to determine if the results of this study may be applied in other populations.
Author(s)
김경미박도양강은화김묘정최병문노규정이은경
Issued Date
2021
Type
Article
Keyword
AccuracyIndocyanine greenMeasurementPlasma volume
DOI
10.1007/s10877-020-00536-5
URI
https://oak.ulsan.ac.kr/handle/2021.oak/7287
https://ulsan-primo.hosted.exlibrisgroup.com/primo-explore/fulldisplay?docid=TN_cdi_proquest_miscellaneous_2408191026&amp;context=PC&amp;vid=ULSAN&amp;lang=ko_KR&amp;search_scope=default_scope&amp;adaptor=primo_central_multiple_fe&amp;tab=default_tab&amp;query=any,contains,A%20modified%20method%20of%20measuring%20plasma%20volume%20with%20indocyanine%20green:%20reducing%20the%20frequency%20of%20blood%20sampling%20while%20maintaining%20accuracy&amp;offset=0&amp;pcAvailability=true
Publisher
JOURNAL OF CLINICAL MONITORING AND COMPUTING
Location
독일
Language
한국어
ISSN
1387-1307
Citation Volume
35
Citation Number
4
Citation Start Page
779
Citation End Page
785
Appears in Collections:
Medicine > Medicine
공개 및 라이선스
  • 공개 구분공개
파일 목록
  • 관련 파일이 존재하지 않습니다.

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.