Reproducibility of radiomic features in SENSE and compressed SENSE: impact of acceleration factors
- Abstract
- Objectives To investigate the impact of acceleration factors on reproducibility of radiomic features in sensitivity encoding (SENSE) and compressed SENSE (CS), compare between SENSE and CS, and identify reproducible radiomic features. Methods Three-dimensional turbo spin echo T1-weighted imaging was performed in 14 healthy volunteers (mean age, 57 years; range, 33-67 years; 7 men) under SENSE and CS with accelerator factors of 5.5, 6.8, and 9.7. Eight anatomical locations (brain parenchyma, salivary glands, masseter muscle, tongue, pharyngeal mucosal space, eyeballs) were evaluated. Reproducibility of radiomic features was evaluated by calculating concordance correlation coefficient (CCC) in reference to the original image (SENSE with acceleration factor of 3.5). Reproducibility of radiomic features among acceleration factors and between SENSE and CS was compared. Results Proportion of radiomic features with CCC > 0.85 in reference to the original image was lower with higher acceleration factors in both SENSE and CS across all anatomical locations (p < .001). Proportion of radiomic features with CCC > 0.85 in reference to the original image was higher in SENSE compared with CS (SENSE, 6.7-7.3% vs CS, 4.4-5.0%; p < .001). Run percentage of gray-level run-length matrix (GLRLM) with wavelet D showed CCC > 0.85 in reference to the original image in both SENSE and CS at acceleration factor of 9.7 in the highest number of anatomical locations. Conclusions Higher acceleration factors resulted in lower reproducibility of radiomic features in both SENSE and CS, and SENSE showed higher reproducibility of radiomic features than CS in reference to the original image. Run percentage of GLRLM with wavelet D was identified as the most reproducible feature.
- Author(s)
- 김민재; 박서영; 박지은; 이현나; 정승채; 최금미
- Issued Date
- 2021
- Type
- Article
- Keyword
- Diagnostic Radiology; Head and Neck; Imaging; Internal Medicine; Interventional Radiology; Medicine; Medicine & Public Health; Neuroradiology; Radiology; Ultrasound
- DOI
- 10.1007/s00330-021-07760-w
- URI
- https://oak.ulsan.ac.kr/handle/2021.oak/7430
https://ulsan-primo.hosted.exlibrisgroup.com/primo-explore/fulldisplay?docid=TN_cdi_proquest_miscellaneous_2502806805&context=PC&vid=ULSAN&lang=ko_KR&search_scope=default_scope&adaptor=primo_central_multiple_fe&tab=default_tab&query=any,contains,Reproducibility%20of%20radiomic%20features%20in%20SENSE%20and%20compressed%20SENSE:%20impact%20of%20acceleration%20factors&offset=0&pcAvailability=true
- Publisher
- EUROPEAN RADIOLOGY
- Location
- 독일
- Language
- 한국어
- ISSN
- 0938-7994
- Citation Volume
- 31
- Citation Number
- 9
- Citation Start Page
- 6457
- Citation End Page
- 6470
-