Prediction accuracy of standard and total keratometry by swept-source optical biometer for multifocal intraocular lens power calculation
- Abstract
- We aimed to compare the refractive outcomes of cataract surgery with diffractive multifocal intraocular lenses (IOLs) using standard keratometry (K) and total keratometry (TK). In this retrospective observational case series study, a total of 302 patients who underwent cataract surgery with multifocal IOL implantation were included. Predicted refractive outcomes were calculated based on the current standard formulas and a new formula developed for TK using K and TK, which were obtained from a swept-source optical biometer. At 2-month postoperatively, median absolute prediction errors (MedAEs) and proportion of eyes within +/- 0.50 diopters (D) of predicted postoperative spherical equivalent (SE) refraction were analyzed. There was no significant difference between MedAEs or proportion of eyes within +/- 0.50D of predicted refraction from K and TK in each formula. In TFNT00 and 839MP IOL cases, there was no difference between MedAEs from K and TK using any formula. In 829MP IOL cases, MedAE from TK was significantly larger than that from K in Barrett Universal II/Barrett TK Universal II (P=0.033). In 677MY IOL cases, MedAE from TK was significantly larger than that from K in Haigis (P=0.020) and Holladay 2 (P=0.006) formulas. In the subgroup analysis for IOL, there was no difference between the proportion of eyes within +/- 0.50 D of predicted refraction from K and TK using any formula. TFNT00 and 839MP IOLs were favorable with TK, with 677MY IOL with K and 829MP IOL being in a neutral position, which necessitates the study that investigates the accuracy of the new TK technology.
- Author(s)
- 이훈; 정재림; 김영준; 김재용; 차흥원
- Issued Date
- 2021
- Type
- Article
- Keyword
- Cataracts; Diseases; Eye surgery; Medical research; Refraction; Surgery
- DOI
- 10.1038/s41598-021-84238-1
- URI
- https://oak.ulsan.ac.kr/handle/2021.oak/7644
https://ulsan-primo.hosted.exlibrisgroup.com/primo-explore/fulldisplay?docid=TN_cdi_doaj_primary_oai_doaj_org_article_dd75375445424dc688167367724911a3&context=PC&vid=ULSAN&lang=ko_KR&search_scope=default_scope&adaptor=primo_central_multiple_fe&tab=default_tab&query=any,contains,Prediction%20accuracy%20of%20standard%20and%20total%20keratometry%20by%20swept-source%20optical%20biometer%20for%20multifocal%20intraocular%20lens%20power%20calculation&offset=0&pcAvailability=true
- Publisher
- SCIENTIFIC REPORTS
- Location
- 영국
- Language
- 한국어
- ISSN
- 2045-2322
- Citation Volume
- 11
- Citation Number
- 1
- Citation Start Page
- 0
- Citation End Page
- 0
-
Appears in Collections:
- Medicine > Medicine
- 공개 및 라이선스
-
- 파일 목록
-
Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.