We aimed to compare the refractive outcomes of cataract surgery with diffractive multifocal intraocular lenses (IOLs) using standard keratometry (K) and total keratometry (TK). In this retrospective observational case series study, a total of 302 patients who underwent cataract surgery with multifocal IOL implantation were included. Predicted refractive outcomes were calculated based on the current standard formulas and a new formula developed for TK using K and TK, which were obtained from a swept-source optical biometer. At 2-month postoperatively, median absolute prediction errors (MedAEs) and proportion of eyes within +/- 0.50 diopters (D) of predicted postoperative spherical equivalent (SE) refraction were analyzed. There was no significant difference between MedAEs or proportion of eyes within +/- 0.50D of predicted refraction from K and TK in each formula. In TFNT00 and 839MP IOL cases, there was no difference between MedAEs from K and TK using any formula. In 829MP IOL cases, MedAE from TK was significantly larger than that from K in Barrett Universal II/Barrett TK Universal II (P=0.033). In 677MY IOL cases, MedAE from TK was significantly larger than that from K in Haigis (P=0.020) and Holladay 2 (P=0.006) formulas. In the subgroup analysis for IOL, there was no difference between the proportion of eyes within +/- 0.50 D of predicted refraction from K and TK using any formula. TFNT00 and 839MP IOLs were favorable with TK, with 677MY IOL with K and 829MP IOL being in a neutral position, which necessitates the study that investigates the accuracy of the new TK technology.
Author(s)
이훈정재림김영준김재용차흥원
Issued Date
2021
Type
Article
Keyword
CataractsDiseasesEye surgeryMedical researchRefractionSurgery
DOI
10.1038/s41598-021-84238-1
URI
https://oak.ulsan.ac.kr/handle/2021.oak/7644
https://ulsan-primo.hosted.exlibrisgroup.com/primo-explore/fulldisplay?docid=TN_cdi_doaj_primary_oai_doaj_org_article_dd75375445424dc688167367724911a3&context=PC&vid=ULSAN&lang=ko_KR&search_scope=default_scope&adaptor=primo_central_multiple_fe&tab=default_tab&query=any,contains,Prediction%20accuracy%20of%20standard%20and%20total%20keratometry%20by%20swept-source%20optical%20biometer%20for%20multifocal%20intraocular%20lens%20power%20calculation&offset=0&pcAvailability=true
Publisher
SCIENTIFIC REPORTS
Location
영국
Language
한국어
ISSN
2045-2322
Citation Volume
11
Citation Number
1
Citation Start Page
0
Citation End Page
0
Appears in Collections:
Medicine > Medicine
공개 및 라이선스
  • 공개 구분공개
파일 목록
  • 관련 파일이 존재하지 않습니다.

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.