KLI

LCD 제조공정의 이온화 장치에 대한 전리방사선 지역노출특성 분석

Metadata Downloads
Abstract
Objectives: This study analyzed the local exposure levels of radiation emitted from the equipment with soft X-ray ionizers to investigate the radiation exposure levels in Liquid Crystal Display(LCD) manufacturing processes.
Methods: This study measured the local radiation levels for the equipment installed in two LCD manufacturing companies. The equipment were installed at diverse processes and equipped with various number of ionizers. The local radiation levels were measured on the surface of the equipment by using direct reading equipment, and the measurements were converted into annual effective dose by considering the radiation exposure time of workers. Statistical analyses were performed to investigate the radiation exposure characteristics.
Results: Annual effective doses for 97.6% of the equipment being measured were less than 1 mSv. However, the range of annual effective doses was 0.004 mSv ~ 2.167 mSv, which indicated a large variation among the equipment. Statistical analyses of the study found that this large variation was raised due to improper shielding of the equipment rather than process and/or equipment characteristics. To pinpoint the cause of this large variation in annual effective dose, this study improved the shielding of the equipment being radiated over 1 mSv and found that their average effective dose was reduced from 1.604 mSv to 0.126 mSv after shielding improvement.
Conclusions: Relatively high exposure levels of radiation were observed in some equipment where their shielding were insufficiently thick and/or sealed. This finding implies that the shielding of the equipment is an important engineering countermeasure to control the radiation exposure levels in industries.
Author(s)
김준범정은교정기효
Issued Date
2021
Type
Article
Keyword
LCD manufacturing companyionizerradiationexposure level
URI
https://oak.ulsan.ac.kr/handle/2021.oak/8915
https://ulsan-primo.hosted.exlibrisgroup.com/primo-explore/fulldisplay?docid=TN_cdi_kiss_primary_3927428&context=PC&vid=ULSAN&lang=ko_KR&search_scope=default_scope&adaptor=primo_central_multiple_fe&tab=default_tab&query=any,contains,LCD%20%EC%A0%9C%EC%A1%B0%EA%B3%B5%EC%A0%95%EC%9D%98%20%EC%9D%B4%EC%98%A8%ED%99%94%20%EC%9E%A5%EC%B9%98%EC%97%90%20%EB%8C%80%ED%95%9C%20%EC%A0%84%EB%A6%AC%EB%B0%A9%EC%82%AC%EC%84%A0%20%EC%A7%80%EC%97%AD%EB%85%B8%EC%B6%9C%ED%8A%B9%EC%84%B1%20%EB%B6%84%EC%84%9D&offset=0&pcAvailability=true
Publisher
한국산업보건학회지
Location
대한민국
Language
한국어
ISSN
2384-132x
Citation Volume
31
Citation Number
4
Citation Start Page
342
Citation End Page
352
Appears in Collections:
Engineering > Aerospace Engineering
공개 및 라이선스
  • 공개 구분공개
파일 목록
  • 관련 파일이 존재하지 않습니다.

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.